C00817 | mctrl_dnspeedset_s, C00818 | mctrl_dnmvoradapt, C00854 | id status – Lenze 9400 User Manual
Page 821: C00878 | status dctrl control input, 14 parameter reference

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
821
14
Parameter reference
14.2
Parameter list | C00817
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00817
C00818
C00854
C00878
Parameter | Name:
C00817 | MCTRL_dnSpeedSet_s
Data type: INTEGER_32
Index: 23758
d
= 5CCE
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
-480000
rpm
480000
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00818 | MCTRL_dnMvorAdapt
Data type: INTEGER_32
Index: 23757
d
= 5CCD
h
From software version V1.5
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
-200.00
%
200.00
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100
Parameter | Name:
C00854 | ID status
Data type: UNSIGNED_32
Index: 23721
d
= 5CA9
h
From software version V3.0
Display range
(min. value | unit | max. value)
0
100
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00878 | Status DCTRL control input
Data type: UNSIGNED_8
Index: 23697
d
= 5C91
h
Display range
(min. value | unit | max. value)
0
1
Subcodes
Info
C00878/1
Status of control inputs
C00878/...
C00878/5
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1