3 attribute table, 14 parameter reference – Lenze 9400 User Manual
Page 913

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
913
14
Parameter reference
14.3
Attribute table
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
14.3
Attribute table
The table of attributes contains information required for a communication with the controller via
parameters.
How to read the table of attributes:
Column
Meaning
Entry
Code
Parameter name
Cxxxxx
Name
Parameter short text (display text)
Text
Type
Parameter type
Selection list
Value from selection list
Bit coded
Bit coded value
Linear value
Value with setting range
String
String
Index
dec
Index under which the parameter is addressed.
The subindex for array variables corresponds to the
Lenze subcode number.
24575 - Lenze code number
Is only required for access via a bus
system.
hex
5FFF
h
- Lenze code number
Data
DS
Data structure
E
Single variable
(only one parameter element)
A
Array variable
(several parameter elements)
DA
Number of array elements (subcodes)
Number
DT
Data type
BITFIELD_8
1 byte bit-coded
BITFIELD_16
2 bytes bit-coded
BITFIELD_32
4 bytes bit-coded
INTEGER_8
1 byte with sign
INTEGER_16
2 bytes with sign
INTEGER_32
4 bytes with sign
UNSIGNED_8
1 byte without sign
UNSIGNED_16
2 bytes without sign
UNSIGNED_32
4 bytes without sign
VISIBLE_STRING [xx]
ASCII string (with character length xx)
Factor
Factor for data transmission via a bus system,
depending on the number of decimal positions
Factor
1 ≡ no decimal positions
10 ≡ 1 decimal position
100 ≡ 2 decimal positions
1000 ≡ 3 decimal positions
10000 ≡ 4 decimal positions
CINH
Writing is only possible if the controller is inhibited CINH
Code
Name
Type
Index
Data
dec
hex
DS
DA
DT
Factor
CINH
Device commands
Selection list
24573
5FFD
E
1
UNSIGNED_32
1
Device command status
Linear value
24572
5FFC
E
1
UNSIGNED_32
1
Service password
Linear value
24571
5FFB
E
1
UNSIGNED_32
1
Application selection
Linear value
24570
5FFA
E
1
INTEGER_32
1
Select motor control
Selection list
24569
5FF9
E
1
UNSIGNED_32
1 CINH
Active application
Linear value
24568
5FF8
E
1
INTEGER_32
1
Device command progress
Linear value
24567
5FF7
E
1
UNSIGNED_32
1
Motor reference speed
Linear value
24564
5FF4
E
1
UNSIGNED_32
1
Switching frequency
Selection list
24557
5FED
E
1
UNSIGNED_32
1
Threshold - standstill recognition
Linear value
24556
5FEC
E
1
UNSIGNED_32
1
Maximum current
Linear value
24553
5FE9
E
1
UNSIGNED_32
100
Config. analog input 1
Selection list
24541
5FDD
E
1
UNSIGNED_32
1
Speed setpoint [rpm]
Linear value
24525
5FCD
A
2
INTEGER_32
1
Actual speed [rpm]
Linear value
24524
5FCC
E
1
INTEGER_32
1
Greyed out = display parameter (read only access)