11.3.4
DC-injection braking
This function extension is available from software version V3.0!
Activate DC-injection braking
To activate DC-injection braking through the application, the bActivateDCBrake control input must
be set to TRUE.
• A change-over to the "Quick stop active" function state is effected and DC-injection braking with
the braking current set in
is carried out.
Flying restart process after cancelling DC injection braking
If the flying restart mode is activated in
and DC-injection braking is cancelled, a flying
restart process is automatically started to determine the current motor speed if the following
conditions are met:
• V/f control or sensorless vector control are selected as motor control in
.
• The position control structure is set to "Phase controller is active" in
.
• The MI_bFlyingSyncBlocked control input of the motor interface is not assigned or set to FALSE.
• The holding brake, if available, is not applied.
Note!
DC-injection braking is only possible if V/f control or sensorless vector control is selected
as motor control type in