25 determine motor parameters, 4drive interface – Lenze 9400 User Manual
Page 71

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
71
4
Drive interface
4.2
Device commands
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.2.25
Determine motor parameters
The
= "72: Determine motor parameters" device command is used to automatically
determine the motor parameters for a third-party motor that are listed in the following table – if
they are not known:
Tip!
Detailed information about the automatic determination of the motor parameters can be
found in the chapter "Motor interface" in the subchapter "
Possible status displays for this device command
Parameter
Info
ASM
SM
Mutual motor inductance
Motor rotor resistance
Motor stator resistance
Motor stator leakage inductance
Motor cosine phi
Motor magnetising current
Status (
Meaning
4752642 Device command in process
4718592 Device command executed successfully
4718593 General fault
4758290 Motor identification cannot be started since the current controller test mode is active.
4758291 Motor identification cannot be started since the V/f test mode is active.
4758292 Motor identification cannot be started because pole position identification is active.
4758293 Motor identification has been aborted.
4758294 Motor identification has been aborted by fault.
4758332 Motor identification aborted due to inconsistent motor parameters.
•
This error message is only available from software version V7.0 onwards.