C00347 | can heartbeat status, C00348 | can status dip switch, C00349 | can setting - dip switch – Lenze 9400 User Manual
Page 771: C00349/1, D in, C00349/2, C00347/1, Displays the, 14 parameter reference

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
771
14
Parameter reference
14.2
Parameter list | C00347
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00347
C00348
C00349
Parameter | Name:
C00347 | CAN heartbeat status
Data type: UNSIGNED_8
Index: 24228
d
= 5EA4
h
"CAN on board" system bus: heartbeat protocol
Selection list
(read only)
0 Unknown
4 Stopped
5 Operational
127 Pre-operational
Subcodes
Info
C00347/1
Status node 1 ... 32
C00347/...
C00347/32
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00348 | CAN status DIP switch
Data type: UNSIGNED_8
Index: 24227
d
= 5EA3
h
• "1" means that the CAN DIP switch has been identified after mains switching and a valid baud rate and node
address have been set.
• "0" means that no CAN DIP switch or no valid setting has been identified or the setting has been overwritten by
writing to code
or
.
Selection list
(read only)
Info
0 Setting not accepted
1 Setting accepted
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00349 | CAN setting - DIP switch
Data type: UNSIGNED_8
Index: 24226
d
= 5EA2
h
Setting of the CAN DIP switch at the last mains connection
Display range
(min. value | unit | max. value)
0
255
Subcodes
Info
C00349/1
Node address
C00349/2
Baud rate:
0: 500 kbps
1: 250 kbps
2: 125 kbps
3: 50 kbps
4: 1 Mbps
5: 20 kbps
6: 10 kbit/s
14: 800 kbps
255: Automatic recognition
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1