C01195 | influence winding i·xt mon, C01196 | s1 torque characteristic i·xt mon, C01197 | starting value i·xt monitoring – Lenze 9400 User Manual
Page 837: C01198 | async. motor: stall protection, C01197, C01195, Tting, C01196/1, C01196/2, C01196/3

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
837
14
Parameter reference
14.2
Parameter list | C01195
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01195
C01196
C01197
C01198
Parameter | Name:
C01195 | Influence winding I²xt mon.
Data type: UNSIGNED_32
Index: 23380
d
= 5B54
h
I
2
xt motor monitoring: Influence of the winding temperature
• By setting "0 %", the time constant for the winding is not considered and the thermal model is only calculated
with the time constant set for the housing/laminated core.
Setting range
(min. value | unit | max. value)
Lenze setting
0
%
100 0 %
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C01196 | S1 torque characteristic I²xt mon.
Data type: UNSIGNED_32
Index: 23379
d
= 5B53
h
• By selecting a characteristic, the permissible motor current is evaluated depending on speed for calculating the
thermal motor utilisation.
Setting range
(min. value | unit | max. value)
0
%
600
Subcodes
Lenze setting
Info
C01196/1
0 %
S1 torque characteristic n1/nn
C01196/2
100 %
S1 torque characteristic I1/In
C01196/3
0 %
S1 torque characteristic n2/nn
C01196/4
100 %
S1 torque characteristic I2/In
C01196/5
100 %
S1 torque characteristic n3/nn
C01196/6
100 %
S1 torque characteristic I3/In
C01196/7
100 %
S1 torque characteristic n4/nn
C01196/8
100 %
S1 torque characteristic I4/In
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C01197 | Starting value I²xt monitoring
Data type: UNSIGNED_32
Index: 23378
d
= 5B52
h
From software version V11.0
Setting range
(min. value | unit | max. value)
Lenze setting
0
%
200 0 %
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C01198 | Async. motor: Stall protection
Data type: UNSIGNED_32
Index: 23377
d
= 5B51
h
Setting range
(min. value | unit | max. value)
Lenze setting
0
%
100 0 %
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1