Safety module has been removed [0x00680007, Control card is defect [0x00680008, Power section is defect [0x00680009 – Lenze 9400 User Manual
Page 626: Mxi1: module is defect or missing [0x0068000a, Mxi2: module is defect or missing [0x0068000b, 0x00680008, 0x0068000a, 0x0068000b, 0x00680009, 0x00680007

13
Diagnostics & fault analysis
13.7
Error messages of the operating system
626
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Safety module has been removed [0x00680007]
Control card is defect [0x00680008]
Power section is defect [0x00680009]
MXI1: Module is defect or missing [0x0068000a]
MXI2: Module is defect or missing [0x0068000b]
Module ID (decimal)
Error ID (decimal)
104: Module identification
7
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
You have tried to remove or change the safety module
during operation.
Switch off the controller, plug in safety module and
switch on the controller again.
• If the error occurs again, the safety module is
defective and must be replaced.
Module ID (decimal)
Error ID (decimal)
104: Module identification
8
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Operating system could not identify the control card.
Consultation with Lenze required.
Module ID (decimal)
Error ID (decimal)
104: Module identification
9
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Operating system could not identify the power section. Consultation with Lenze required.
Module ID (decimal)
Error ID (decimal)
104: Module identification
10
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Operating system could not identify the extension
module in module slot MXI1.
• Use a different extension module.
• Please contact Lenze.
Module ID (decimal)
Error ID (decimal)
104: Module identification
11
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Operating system could not identify the extension
module in module slot MXI2.
• Use a different extension module.
• Please contact Lenze.