Parameter reference
14.2
Parameter list | C02548
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02548
C02549
Parameter | Name:
C02548 | DI_bErrors
Data type: UNSIGNED_32
Index: 22027
d
= 560B
h
Display of the digital error signals of the
Selection list
(read only)
0 FALSE
1 TRUE
Subcodes
Info
C02548/1
DI_bResetError1
C02548/2
DI_bResetError2
C02548/3
DI_bResetError3
C02548/4
DI_bSetExternError
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02549 | Drive interface: Signals
Data type: UNSIGNED_32
Index: 22026
d
= 560A
h
Display of the digital signals of the
Selection list
(read only)
0 FALSE
1 TRUE
Subcodes
Info
C02549/1
DI_bSetCInh
C02549/2
Reserved
C02549/3
Reserved
C02549/4
DI_bSwitchOn
C02549/5
Reserved
C02549/6
DI_bReady
C02549/7
DI_bFailActive
C02549/8
DI_bImpActive
C02549/9
DI_bCinhActive
C02549/10
DI_bWarningActive
C02549/11
DI_bUVDetected
C02549/12
DI_bOVDetected
C02549/13
DI_bMainSupplyOk
C02549/14
DI_bReadyToSwitchOn
C02549/15
DI_bOperationEnabled
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1