C00469 | keypad: fct. stop key, C00490 | position encoder selection, C00494 | motor standstill time constant – Lenze 9400 User Manual
Page 792: C00495 | motor encoder selection, C00495, Ted in, C00490, And are c, C00469, 14 parameter reference

14
Parameter reference
14.2
Parameter list | C00469
792
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00469
C00490
C00494
C00495
Parameter | Name:
C00469 | Keypad: Fct. STOP key
Data type: UNSIGNED_8
Index: 24106
d
= 5E2A
h
Selection list
(Lenze setting printed in bold)
0 No response
1 Inhibit controller
2 Activate quick stop
3 Stop application
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00490 | Position encoder selection
Data type: UNSIGNED_16
Index: 24085
d
= 5E15
h
Chapter "
" provides you with more information on parameter setting.
Selection list
(Lenze setting printed in bold)
0 Resolver on X7
1 Encoder on X8
4 Encoder signal on LS_Feedback
10 Motor encoder (C00495)
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00494 | Motor standstill time constant
Data type: UNSIGNED_32
Index: 24081
d
= 5E11
h
Setting range
(min. value | unit | max. value)
Lenze setting
0
ms
100000 0 ms
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00495 | Motor encoder selection
Data type: UNSIGNED_16
Index: 24080
d
= 5E10
h
Selection list
(Lenze setting printed in bold)
0 Resolver on X7
1 Encoder on X8
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1