Encoder: open circuit [0x007b001b, Brake transistor: ixt overload [0x007b001c, Brake resistor: i·xt overload [0x007b001d – Lenze 9400 User Manual
Page 653: Motor: actual current value > c00620 [0x007b001e, 0x007b001d, 0x007b001c, 0x007b001b, 0x007b001e, 13 diagnostics & fault analysis

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
653
13
Diagnostics & fault analysis
13.7
Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Encoder: Open circuit [0x007b001b]
Brake transistor: Ixt overload [0x007b001c]
Brake resistor: I²xt overload [0x007b001d]
Motor: Actual current value > C00620 [0x007b001e]
Module ID (decimal)
Error ID (decimal)
123: Motor control
27
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
• Encoder cable interrupted.
• Encoder defective.
• Faulty parameter setting of the encoder.
• Interruption of the light path of laser measuring
systems.
• Insufficient reflection of the light of laser measuring
systems.
Note:
The encoder open-circuit monitoring for incremental
encoders (
= "0: Incremental encoder (TTL
signal)") requires a signal amplitude > 3.5 V!
If the signal amplitude is lower than 3.0 V, the error
response parameterised in
• Check encoder cable.
• Check encoder.
• Check parameter setting (
).
• Switch off the monitoring function (
="3") if no
encoder is used.
• Correct the light path (for laser measuring systems).
• Improve the reflection (for laser measuring systems).
Module ID (decimal)
Error ID (decimal)
123: Motor control
28
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Too frequent and too long braking processes.
Check drive dimensioning.
Module ID (decimal)
Error ID (decimal)
123: Motor control
29
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Too frequent and too long braking processes.
• Check drive dimensioning.
• Check parameter setting (
).
Module ID (decimal)
Error ID (decimal)
123: Motor control
30
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The instantaneous value of the motor current has
exceeded the value set in
• Reduce maximum current (
• Change response (
).