Motor data are inconsistent [0x007b0003, Motor: phase resistance too high [0x007b0004, 0x007b0003 – Lenze 9400 User Manual
Page 648: 0x007b0001, 0x007b0002, 0x007b0006, 0x007b0004, 13 diagnostics & fault analysis

13
Diagnostics & fault analysis
13.7
Error messages of the operating system
648
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Motor: Calculated motor impedance unrealistic [0x007b0001]
Motor: Calculated mutual inductance unrealistic [0x007b0002]
Motor data are inconsistent [0x007b0003]
Motor: Phase resistance too high [0x007b0004]
Motor: Device current too low for rated magnetisation [0x007b0006]
Module ID (decimal)
Error ID (decimal)
123: Motor control
1
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Faulty motor parameterisation.
Check motor parameters.
Module ID (decimal)
Error ID (decimal)
123: Motor control
2
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Faulty motor parameterisation.
Check motor parameters.
Module ID (decimal)
Error ID (decimal)
123: Motor control
3
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Faulty motor parameterisation.
Check motor parameters.
Module ID (decimal)
Error ID (decimal)
123: Motor control
4
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Faulty motor parameterisation.
Check motor parameters.
Module ID (decimal)
Error ID (decimal)
123: Motor control
6
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Controller current is too low for rated magnetisation, i.e.
the controller cannot energise the motor sufficiently.
Check drive dimensioning.