C00106 | quick stop s-ramp time, C00107 | ref. for quick stop dec. time, C00114 | dig. input x: terminal polarity – Lenze 9400 User Manual
Page 743: C00118 | dig. output. x: terminal polarity, C00114, Terised in, C00118, Into, C00106, C00107

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
743
14
Parameter reference
14.2
Parameter list | C00106
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00106
C00107
C00114
C00118
Parameter | Name:
C00106 | Quick stop S-ramp time
Data type: UNSIGNED_32
Index: 24469
d
= 5F95
h
S-ramp time in [%] relating to the deceleration time set under
Basic function "
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
%
100.00 0.00 %
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100
Parameter | Name:
C00107 | Ref. for quick stop dec. time
Data type: UNSIGNED_8
Index: 24468
d
= 5F94
h
Reference for the deceleration time set in
Basic function "
Selection list
(Lenze setting printed in bold)
0 Motor reference speed (C00011)
1 Current speed
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00114 | Dig. input x: Terminal polarity
Data type: UNSIGNED_8
Index: 24461
d
= 5F8D
h
"0" = positive logic (HIGH level = TRUE, LOW level = FALSE)
"1" = negative logic (HIGH level = FALSE, LOW level = TRUE)
Setting range
(min. value | unit | max. value)
0
1
Subcodes
Lenze setting
Info
C00114/1
0
Terminal polarity - digital input 1 ... 8
C00114/...
C00114/8
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00118 | Dig. output. x: Terminal polarity
Data type: UNSIGNED_8
Index: 24457
d
= 5F89
h
"0" ≡ positive logic (TRUE ≡ HIGH level, FALSE ≡ LOW level)
"1" ≡ negative logic (FALSE ≡ HIGH level, TRUE ≡ LOW level)
Setting range
(min. value | unit | max. value)
0
1
Subcodes
Lenze setting
Info
C00118/1
0
Terminal polarity - digital output 1 ... 4
C00118/...
C00118/4
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1