C00367 | can sync rx identifier, C00368 | can sync tx identifier, C00369 | can sync transmission cycle time – Lenze 9400 User Manual
Page 775: C00367, C00368, C00369/1, C00367 c00368, C00369, 14 parameter reference

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
775
14
Parameter reference
14.2
Parameter list | C00367
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00367
C00368
C00369
Parameter | Name:
C00367 | CAN SYNC Rx identifier
Data type: UNSIGNED_32
Index: 24208
d
= 5E90
h
Identifier by means of which the sync slave is to receive sync telegrams.
• Mapping of the CANopen object
(see DS301 V4.02).
"CAN on board" system bus: sync telegram
Setting range
(min. value | unit | max. value)
Lenze setting
0
2047 128
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00368 | CAN SYNC Tx identifier
Data type: UNSIGNED_32
Index: 24207
d
= 5E8F
h
Identifier by means of which the sync master is to transmit sync telegrams.
• Mapping of the CANopen object
(see DS301 V4.02).
"CAN on board" system bus: sync telegram
Setting range
(min. value | unit | max. value)
Lenze setting
0
2047 128
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00369 | CAN sync transmission cycle time
Data type: UNSIGNED_16
Index: 24206
d
= 5E8E
h
Cycle during which the sync master is to transmit sync telegrams.
• If "0 ms" is set (Lenze setting), no sync telegrams are generated.
• Mapping of the CANopen object
(see DS301 V4.02).
"CAN on board" system bus: sync telegram
Setting range
(min. value | unit | max. value)
0
ms
65535
Subcodes
Lenze setting
Info
C00369/1
0 ms
Transmission cycle time for CAN on board
C00369/2
0 ms
Transmission cycle time for CAN module in MXI1/MXI2
C00369/3
0 ms
- (no meaning)
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1