3 emergency telegram, Emergency telegram, 9"can on board" system bus – Lenze 9400 User Manual
Page 338

9
"CAN on board" system bus
9.9
Monitoring
338
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
9.9.3
Emergency telegram
If the error status changes because an internal device error occurs or has been eliminated, the NMT
master receives an emergency telegram once with the following structure:
Example
Tip!
A detalied description can be found in CAN specification DS301, V4.02.
1st byte
2nd byte
3rd byte
4th byte
5th byte
6th byte
7th byte
8th byte
Emergency error code
Error register
Manufacturer-specific error message
LOW byte
HIGH byte
0x00
(reserved)
LOW word
HIGH word
LOW byte
HIGH byte
LOW byte
HIGH byte
See table below
• With emergency error code 0x1000: Lenze error number
• All other emergency error codes have a value of "0" here.
Emergency error code
Error register
Cause
0x0000
0xXX
One of several errors eliminated
0x00
One error has been eliminated (error-free status afterwards)
0x1000
0x01
Generic error
• In the standard device, an error has occurred with the error
response "Fault", "Trouble", "Quick stop by trouble", "Warning",
"Warning locked" or "System fault".
• Error message is the Lenze error number (
).
• For error cause see fault error description (
).
0x3100
0x01
Supply voltage of standard device faulty or failed
0x8100
0x11
Communication error (warning)
0x8130
0x11
Life guarding error or heartbeat error
0x8150
0x11
Collision of identifiers (COB-IDs): An identifier parameterised for
reception is also used for transmission.
0x8210
0x11
PDO length shorter than expected
0x8220
0x11
PDO length greater than expected
0x8700
0x11
Monitoring of the sync telegram
1st byte
2nd byte
3rd byte
4th byte
5th byte
6th byte
7th byte
8th byte
Emergency error code
Error register
Manufacturer-specific error message
0x00
0x10
0x01
0x00
(reserved)
0x1B
0x00
0x7B
0x00
Generic error
Lenze error message 0x007b001b: Encoder wire
breakage.
Error messages of the operating system
Corresponding error-free message: Value
"0x00000000"