11 basic drive functions – Lenze 9400 User Manual
Page 568

11
Basic drive functions
11.13
Cam data management
568
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.13.5
Invalid cam data due to changed machine parameters
This function extension is available from software version V4.0!
If one or more machine parameters affecting the internal scaling of the cam data are changed, the
message "Cam Data: Invalidated due to change of mechanical data" (error number
) is
entered into the logbook and the error response "Warning" occurs.
• The cam data are no longer valid and have to be recalculated.
• The warning is automatically reset if the
= "503: Calculate Cam Data" device command
is executed.
Machine parameters affecting the internal scaling of the cam data:
Parameter
Info
Selection of the motor control
Resolution of an encoder revolution
Gearbox factor - motor (if motor = reference source)
Gearbox factor - position encoder (if position encoder = reference source)
Feed constant
Position control structure