Jerk has been limited [0x00b8000e, Maximum speed exceeded [0x00b80010, Maximum acceleration exceeded [0x00b80011 – Lenze 9400 User Manual
Page 701: 0x00b8000e, 0x00b80011, 0x00b80010, 0x00b8000f, 13 diagnostics & fault analysis

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
701
13
Diagnostics & fault analysis
13.7
Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Jerk has been limited [0x00b8000e]
Position target outside the software limit positions [0x00b8000f]
Maximum speed exceeded [0x00b80010]
Maximum acceleration exceeded [0x00b80011]
Module ID (decimal)
Error ID (decimal)
184: Basic drive functions
14
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The requested S-ramp time is lower than the minimum
and has been limited to this S-
ramp time.
• Increase S-ramp time of the traversing profile of the
basic function (manual jog, homing, or positioning).
• Reduce minimum S-ramp time (
• Deactivate monitoring of the limit values by the basic
function "Limiter".
Module ID (decimal)
Error ID (decimal)
184: Basic drive functions
15
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
It was tried to position to a target outside the software
limit positions.
• Select a target within the software limit positions.
• Increase permissible traversing range (change setting
of the software limit positions).
• Deactivate monitoring of the software limit positions
by the basic function "Limiter".
Module ID (decimal)
Error ID (decimal)
184: Basic drive functions
16
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The max. speed parameterised in
been exceeded.
• Reduce speed.
• Increase maximum speed (
).
• Deactivate monitoring of the limit values by the basic
function "Limiter".
Module ID (decimal)
Error ID (decimal)
184: Basic drive functions
17
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The max. acceleration parameterised in
been exceeded.
• Reduce acceleration.
• Increase maximum acceleration (
• Deactivate monitoring of the limit values by the basic
function "Limiter".