6encoder evaluation – Lenze 9400 User Manual
Page 259

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
259
6
Encoder evaluation
6.3
Parameter setting
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Short overview of the parameters:
Parameter
Info
Lenze setting
Value Unit
Encoder type
SSI encoder
SSI encoder: Bit rate
400 kbps
SSI encoder: Data word length
24 Bit
SSI enc.: Partword 1 start
0
SSI enc.: Partword 1 length
24
SSI enc.: Partword 1 coding
gray coded
Position encoder selection
Encoder on X8
Motor encoder selection
Resolver on X7
Gearbox factor numerator: position encoder
1200
Gearbox factor denominator: position encoder
400
Feed constant
1200 mm
Position control structure
Position controller is active
C05271
Encoder evaluation
32-bit encoder signal
C05272
Encoder mounting position
Left
C05273
Single turn resolution
4096 Steps/rev
C05274
Resolution Multiturn
4096 Rev