2 parameter list, C00002 | device command, C00002 – Lenze 9400 User Manual
Page 720: Ure protection, Ecute device command, T in, C00005, C00003, Ands, C00006

14
Parameter reference
14.2
Parameter list
720
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
14.2
Parameter list
This chapter lists all parameters of the operating system in numerically ascending order.
C00002
Note!
The parameter descriptions are based on the software version V12.00.xx.
Parameter | Name:
C00002 | Device command
Data type: UNSIGNED_32
Index: 24573
d
= 5FFD
h
Device commands
•
shows the status of the last executed device command.
you can query the current status of the device control.
Note:
Before switching off the supply voltage after a device command has been executed, check the successful execution
of the device command via the status display in
The meaning of the status display in
can be obtained from the subchapter for the corresponding device
command in chapter "
Selection list
(Lenze setting printed in bold)
Info
0 Load Lenze setting
Resets parameters to Lenze setting.
• Only possible when the application has stopped and
the controller is inhibited.
1 Load start parameters
Loads parameters from the memory module.
• Only possible when the application has stopped and
the controller is inhibited.
2 ENP: Load plant data
Reads plant data from the electronic motor nameplate.
• Only possible when the application has stopped and
the controller is inhibited.
5 Activate application
Activates the application selected under
• Whether the application is also started, depends on
the auto-start setting selected.
• Only possible when the application has stopped.
7 Save selected application
Selects the active application as start application.
11 Save start parameters
Saves parameters fail-safe in the memory module.
20 Delete logbook
Deletes all logbook entries.
21 Archive logbook
Exports logbook entries to file.
27 Device search function ON
28 Device search function OFF
31 Start application
32 Stop application
33 Reset program
Carries out a reset.
• All variables are reset to their initialisation value.
• The situation corresponds to the start of a new
program loaded into the control (cold start).
34 Delete program
Carries out a reset (source).
• All variables are reset to their initialisation value.
• The application program is deleted and the controller
is reset to its original state.