34 unbind/bind ethernet module mxi1, 4drive interface – Lenze 9400 User Manual
Page 81

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
81
4
Drive interface
4.2
Device commands
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.2.34
Unbind/bind Ethernet module MXI1
The
= "101: Unbind/bind Ethernet module: MXI1" device command is used to reinitialise
the Ethernet interface of an Ethernet communication module in module slot MXI1, e. g. to accept a
newly set IP or gateway address without mains switching.
Tip!
Detailed information on the Ethernet communication module (E94AYCEN) can be found in
the "Ethernet" Communication Manual.
Possible status displays for this device command
Related device commands
Unbind/bind Ethernet module MXI2
Status (
Meaning
6653186 Device command in process
6619136 Device command executed successfully
6619137 General fault