C02906 | online change state, C02908 | product count, C02909 | active product – Lenze 9400 User Manual
Page 906: C02910 | product name, C02911 | product choice, C02908, C02906, C02909, C02910, C02911

14
Parameter reference
14.2
Parameter list | C02906
906
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02906
C02908
C02909
C02910
C02911
Parameter | Name:
C02906 | Online Change State
Data type: UNSIGNED_32
Index: 21669
d
= 54A5
h
From software version V3.0
Basic function "Cam data management":
Selection list
(read only)
0 Ready
5 Initialisation
7 Saving is active
8 Loading is active
11 Waiting for controlled acceptance
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02908 | Product Count
Data type: UNSIGNED_32
Index: 21667
d
= 54A3
h
From software version V3.0
Display of the highest product number +1 of the cam data currently being processed
Basic function "
Display range
(min. value | unit | max. value)
0
0
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02909 | Active Product
Data type: UNSIGNED_32
Index: 21666
d
= 54A2
h
From software version V3.0
Display of the product number of the active product of the cam data currently being processed
Basic function "
Display range
(min. value | unit | max. value)
0
0
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02910 | Product Name
Data type: VISIBLE_STRING
Index: 21665
d
= 54A1
h
From software version V3.0
Basic function "
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Character length: 16
Parameter | Name:
C02911 | Product Choice
Data type: UNSIGNED_32
Index: 21664
d
= 54A0
h
From software version V3.0
Changing cam data via parameterisation
Setting range
(min. value | unit | max. value)
Lenze setting
0
255 0
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1