Controller enabled [0x00750001, Controller in sto state [0x00750003, Controller: pulse inhibit is active [0x00750005 – Lenze 9400 User Manual
Page 641: Plc configuration invalid [0x00750006, Heatsink: temperature > c00122 [0x00770000, 0x00750001, 0x00750003, 0x00750005, 0x00770000, 0x00750006

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
641
13
Diagnostics & fault analysis
13.7
Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Controller enabled [0x00750001]
Controller in STO state [0x00750003]
Controller: Pulse inhibit is active [0x00750005]
PLC configuration invalid [0x00750006]
Heatsink: Temperature > C00122 [0x00770000]
Module ID (decimal)
Error ID (decimal)
117: Device control
1
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The controller is enabled and has the "Operation" state. - (Information only)
Module ID (decimal)
Error ID (decimal)
117: Device control
3
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The controller has received the "Safe torque off (STO)"
request by the safety module and is now in the "Safe
torque off active" device state.
- (Information only)
Module ID (decimal)
Error ID (decimal)
117: Device control
5
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The pulse inhibit is active in the controller.
- (Information only)
Module ID (decimal)
Error ID (decimal)
117: Device control
6
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
An invalid control configuration has occurred.
Load a different application.
Module ID (decimal)
Error ID (decimal)
119: Temperature monitoring
0
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Heatsink temperature higher than variable temperature
limit (
• Ambient controller temperature too high.
• Dirty fan or ventilation slots.
• Value set under C00122 is too low.
• Check control cabinet temperature.
• Clean filter.
• Clean controller.