C00387 | can node guarding activity, C00388 | can node guarding status, C00390 | can error register (ds301v402) – Lenze 9400 User Manual
Page 782: C00390, C00387, C00388/1, Displays the, C00392, 14 parameter reference

14
Parameter reference
14.2
Parameter list | C00387
782
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00387
C00388
C00390
Parameter | Name:
C00387 | CAN Node Guarding Activity
Data type: BITFIELD_32
Index: 24188
d
= 5E7C
h
"CAN on board" system bus: node guarding protocol
Display area
0x00000000
0xFFFFFFFF
Value is bit-coded:
Bit 0 Node guarding of node 1
... ...
Bit 31 Node guarding of node 32
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00388 | CAN node guarding status
Data type: UNSIGNED_8
Index: 24187
d
= 5E7B
h
"CAN on board" system bus: node guarding protocol
Selection list
(read only)
0 Unknown
4 Stopped
5 Operational
127 Pre-operational
Subcodes
Info
C00388/1
Status node 1 ... 32
C00388/...
C00388/32
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00390 | CAN Error Register (DS301V402)
Data type: BITFIELD_8
Index: 24185
d
= 5E79
h
Mapping of the CANopen object
(see DS301 V4.02).
Display area
0x00
0xFF
Value is bit-coded:
Info
Bit 0 Generic error
Currently only bit 0 and bit 4 contain the corresponding
information.
Bit 1 Current error (not used)
Bit 2 Voltage error (not used)
Bit 3 Temperature error (not used)
Bit 4 Communication error
Bit 5 Dev. prof. spec. err (not used)
Bit 6 Reserved
Bit 7 Manuf. spec. error (not used)
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1