No parameters for module in mxi1 [0x0090000a, No parameters for module in mxi2 [0x0090000b, Mains voltage is switched on [0x00910000 – Lenze 9400 User Manual
Page 678: 0x0090000c, 0x00910000, 0x0090000a, 0x0090000b, 13 diagnostics & fault analysis

13
Diagnostics & fault analysis
13.7
Error messages of the operating system
678
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
No parameters for module in MXI1 [0x0090000a]
No parameters for module in MXI2 [0x0090000b]
Disconnection in the case of par. storage [0x0090000c]
Mains voltage is switched on [0x00910000]
Module ID (decimal)
Error ID (decimal)
144: Parameter manager
10
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The parameter set contains no parameters for the
module inserted in MXI1.
Integrate the module inserted in MXI1 into the Engineer
project and then retransmit the parameter set to the
controller.
Module ID (decimal)
Error ID (decimal)
144: Parameter manager
11
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The parameter set contains no parameters for the
module inserted in MXI2.
Integrate the module inserted in MXI2 into the Engineer
project and then retransmit the parameter set to the
controller.
Module ID (decimal)
Error ID (decimal)
144: Parameter manager
12
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The supply voltage has failed before the saving of the
parameter set could be completed. In the case of a device
replacement/firmware update, the parameter set can no
longer be established automatically.
Save the start parameters again, and in doing this,
ensure that the supply voltage is applied until the saving
process has been completed. Afterwards acknowledge
the error message with "Reset error".
Module ID (decimal)
Error ID (decimal)
145: Lenze runtime system
0
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Mains voltage has been switched on.
- (Information only)