C02596 | grinding speed, C02597 | accel./decel. time - grinding, C02598 | grinding on time – Lenze 9400 User Manual
Page 865: C02599 | grinding off time, C02600 | acceleration time feedf. control, C02596, C02597, C02598, C02599, C02600

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
865
14
Parameter reference
14.2
Parameter list | C02596
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02596
C02597
C02598
C02599
C02600
Parameter | Name:
C02596 | Grinding speed
Data type: INTEGER_32
Index: 21979
d
= 55DB
h
Basic function "
Setting range
(min. value | unit | max. value)
Lenze setting
0
rpm
300 100 rpm
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02597 | Accel./decel. time - grinding
Data type: UNSIGNED_32
Index: 21978
d
= 55DA
h
Basic function "
Setting range
(min. value | unit | max. value)
Lenze setting
0.000
s
60.000 1.000 s
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1000
Parameter | Name:
C02598 | Grinding ON time
Data type: UNSIGNED_32
Index: 21977
d
= 55D9
h
Basic function "
Setting range
(min. value | unit | max. value)
Lenze setting
0.2
s
2.0 0.5 s
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10
Parameter | Name:
C02599 | Grinding OFF time
Data type: UNSIGNED_32
Index: 21976
d
= 55D8
h
Basic function "
Setting range
(min. value | unit | max. value)
Lenze setting
0.2
s
2.0 0.5 s
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10
Parameter | Name:
C02600 | Acceleration time feedf. control
Data type: UNSIGNED_32
Index: 21975
d
= 55D7
h
From software version V3.0
Basic function "
Setting range
(min. value | unit | max. value)
Lenze setting
0.000
s
1000.000 0.000 s
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1000