C02561 | speed feedforw. control gain, C02562 | filter time constant, C02564 | service code – Lenze 9400 User Manual
Page 858: C02567 | control mode, Is determined, C02562, Iltering, 14 parameter reference

14
Parameter reference
14.2
Parameter list | C02561
858
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02561
C02562
C02564
C02567
Parameter | Name:
C02561 | Speed feedforw. control gain
Data type: INTEGER_32
Index: 22014
d
= 55FE
h
From software version V1.5
Percentage reduction of the speed feedforward control of the profile generator
• Required in some applications if a 100 % speed feedforward control causes overshoots.
• Only effective for the basic functions "Positioning", "Homing" and "Manual jog".
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
%
200.00 100.00 %
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100
Parameter | Name:
C02562 | Filter time constant
Data type: UNSIGNED_32
Index: 22013
d
= 55FD
h
From software version V7.0
Setting range
(min. value | unit | max. value)
Lenze setting
0.000
s
60.000 0.002 s
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1000
Parameter | Name:
C02564 | Service code
Data type: BITFIELD_8
Index: 22011
d
= 55FB
h
From software version V9.0
Setting range
Lenze setting
0x00
0xFF 0x00 (decimal: 0)
Value is bit-coded: ( = bit set)
Bit 0 Option 0
Bit 1 Option 1
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02567 | Control mode
Data type: UNSIGNED_32
Index: 22008
d
= 55F8
h
Selection list
(read only)
0 Position control
1 Speed control
2 Torque control
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1