C00993 | flying restart: integration time, C00994 | flying restart: min. deviation, C00995 | flying restart: delay time – Lenze 9400 User Manual
Page 831: C00998 | vfc: frequency setpoint, C00993, C00995, C00994, 14 parameter reference

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
831
14
Parameter reference
14.2
Parameter list | C00993
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00993
C00994
C00995
C00998
Parameter | Name:
C00993 | Flying restart: Integration time
Data type: UNSIGNED_32
Index: 23582
d
= 5C1E
h
From software version V3.0
Setting range
(min. value | unit | max. value)
Lenze setting
1
ms
6000 60 ms
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00994 | Flying restart: Min. deviation
Data type: UNSIGNED_32
Index: 23581
d
= 5C1D
h
From software version V3.0
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
°
90.00 5.00 °
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100
Parameter | Name:
C00995 | Flying restart: Delay time
Data type: UNSIGNED_32
Index: 23580
d
= 5C1C
h
From software version V3.0
Setting range
(min. value | unit | max. value)
Lenze setting
0
ms
10000 0 ms
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00998 | VFC: Frequency setpoint
Data type: INTEGER_32
Index: 23577
d
= 5C19
h
From software version V3.0
Display range
(min. value | unit | max. value)
-800.0
Hz
800.0
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10