C00464 | keypad: mode, C00465 | keypad: timeout welcome screen, C00466 | keypad: default parameter – Lenze 9400 User Manual
Page 791: C00467 | keypad: default welcome screen, 14 parameter reference

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
791
14
Parameter reference
14.2
Parameter list | C00464
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00464
C00465
C00466
C00467
C00468
Parameter | Name:
C00464 | Keypad: Mode
Data type: UNSIGNED_16
Index: 24111
d
= 5E2F
h
From software version V5.0
Definition of the mode in which the keypad attached is to be activated.
• If both
keypad versions (V1.0 and V2.0) are used, the Lenze setting is to be maintained.
• If only the new keypad V2.0 is used, the initialisation time of the keypad can be reduced by changing over to
mode 2. Furthermore mode 2 supports greater future keypad files.
Note: If mode 2 is selected, the keypad V1.0 can no longer be operated on the controller!
Selection list
(Lenze setting printed in bold)
Info
0 Mode 1
For keypad V1.0 and V2.0
1 Mode 2
Only for keypad V2.0
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00465 | Keypad: Timeout welcome screen
Data type: UNSIGNED_8
Index: 24110
d
= 5E2E
h
Selection list
(Lenze setting printed in bold)
0 Never show welcome screen
5 5 min
15 15 min
30 30 min
60 60 min
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00466 | Keypad: Default parameter
Data type: UNSIGNED_16
Index: 24109
d
= 5E2D
h
Setting range
(min. value | unit | max. value)
Lenze setting
0
65535 0
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00467 | Keypad: Default welcome screen
Data type: UNSIGNED_8
Index: 24108
d
= 5E2C
h
Selection list
(Lenze setting printed in bold)
0 Main menu
1 Parameter list
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00468 | Service code
Data type: UNSIGNED_8
Index: 24107
d
= 5E2B
h
This code is for device-internal use only and must not be written to by the user!