1 memory distribution, Memory distribution ( 554), 11 basic drive functions – Lenze 9400 User Manual
Page 554

11
Basic drive functions
11.13
Cam data management
554
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.13.1.1 Memory distribution
From software version V5.0
there are three different storage modes for the distribution of the cam
data memory in the controller. The specification of the storage mode is effected automatically by
the »Engineer« when the cam data file is generated.
Note!
For controllers
with a software version lower than V5.0
the memory distribution always
corresponds to storage mode 1 (see following table), i. e. the max. size of the cam data
file is limited to 256 kBytes.
Storage modes 2 and 3 automatically provide a greater memory for an extensive amount
of cam data, however, in return certain functions are no longer supported (e. g. changing
cam data via parameterisation).
Memory distribution of the cam data
Display in
[bytes]
Storage mode
1
2*
3*
Memory module
-
262144 bytes
(256 kBytes)
524288 bytes
(512 kBytes)
1048576 bytes
(1024 kBytes)
Internal RAM for quick download
262144 bytes
(256 kBytes)
0 bytes
0 bytes
Internal RAM for online change
131072 bytes
(128 kBytes)
262144 bytes
(256 kBytes)
0 bytes
Internal RAM for cam data
131072 bytes
(128 kBytes)
262144 bytes
(256 kBytes)
524288 bytes
(512 kBytes)
* Only from software version V5.0
Functions supported
Storage mode
1
2*
3*
Changing cam data via parameterisation
Quick download to the RAM
Device command "
"
Device command "
Device command "
"
Device command "
"