Failure of a mains phase [0x007b003f, Brake chopper: ixt > c00570 [0x007b0040, Brake resistor: i2t > c00572 [0x007b0041 – Lenze 9400 User Manual
Page 661: Power section is defect [0x007b0042, 0x007b003f, 0x007b0040, 0x007b0041, 0x007b0042, 13 diagnostics & fault analysis

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
661
13
Diagnostics & fault analysis
13.7
Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Failure of a mains phase [0x007b003f]
Brake chopper: Ixt > C00570 [0x007b0040]
Brake resistor: I2t > C00572 [0x007b0041]
Power section is defect [0x007b0042]
Module ID (decimal)
Error ID (decimal)
123: Motor control
63
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Missing mains phase.
Note: This monitoring is only available for devices
≥ 75 kW (type 8S and bigger).
Check mains connection.
Module ID (decimal)
Error ID (decimal)
123: Motor control
64
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Frequent and too long braking.
• Check drive dimensioning.
• Check setting in
.
Module ID (decimal)
Error ID (decimal)
123: Motor control
65
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Frequent and too long braking.
• Check drive dimensioning.
• Check setting in
.
• Check settings for brake resistor (
).
Module ID (decimal)
Error ID (decimal)
123: Motor control
66
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Device error
Mains switching
• Please contact Lenze if the problem occurs again.