Ta" (error number, 0x00b80034, 0x00b80032 – Lenze 9400 User Manual
Page 711: 0x00b80033, 13 diagnostics & fault analysis

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
711
13
Diagnostics & fault analysis
13.7
Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Int. overflow C02647 (homing: Acceleration 2) [0x00b80032]
Int. overflow C02670 (positioner: Tol. for target position) [0x00b80033]
Cam data: Invalidated due to change of mechanical data [0x00b80034]
Module ID (decimal)
Error ID (decimal)
184: Basic drive functions
50
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
From software version V3.0
Due to a subsequent change of the machine parameters
for gearbox ratio, feed constant, or resolution of an
encoder revolution, the value set in the parameter
cannot be displayed in the internal unit. See chapter
"
Max. position, speed, and acceleration that can be
".
• Check machine parameters and adapt them if
required.
• Change setting in
Module ID (decimal)
Error ID (decimal)
184: Basic drive functions
51
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
From software version V3.0
Due to a subsequent change of the machine parameters
for gearbox ratio, feed constant, or resolution of an
encoder revolution, the value set in the parameter
cannot be displayed in the internal unit. See chapter
"
Max. position, speed, and acceleration that can be
".
• Check machine parameters and adapt them if
required.
• Change setting in
Module ID (decimal)
Error ID (decimal)
184: Basic drive functions
52
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
From software version V4.0
One or several machine parameters have been changed
that have an influence on the internal scaling of the Cam
data. The Cam data has to be recalculated. See chapter
"
Invalid Cam data due to changed machine parameters
Execute device command
Data". This automatically resets the warning.