C02871 | voltage reserve, C02900 | user password, C02901 | cammemory – Lenze 9400 User Manual
Page 904: C02900, C02901/1, C02901/2, C02901/3, C02901, Is maintai, Ssword into

14
Parameter reference
14.2
Parameter list | C02870
904
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02870
C02871
C02900
C02901
Parameter | Name:
C02870 | Service code
Data type: UNSIGNED_32
Index: 21705
d
= 54C9
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C02871 | Voltage reserve
Data type: UNSIGNED_32
Index: 21704
d
= 54C8
h
From software version V12.0
Voltage reserve at the transition point to field weakening
• Only relevant for servo control for asynchronous motor (selection "2" in
Setting range
(min. value | unit | max. value)
Lenze setting
1
%
20 5 %
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02900 | User Password
Data type: VISIBLE_STRING
Index: 21675
d
= 54AB
h
From software version V3.0
If the cam data are provided with a user password, the defined user password must be entered once to execute the
following actions:
• Changing the cam data via parameter setting
• Loading/saving the cam data
Validity
The user password entered is maintained until the next download, mains switching, or until reset by the user
(logout).
• You can "logout" deliberately by entering an invalid password.
Basic function "
Read access Write access CINH PLC STOP No transfer
Character length: 22
Parameter | Name:
C02901 | CamMemory
Data type: UNSIGNED_32
Index: 21674
d
= 54AA
h
From software version V5.0
Basic function "Cam data management":
Display range
(min. value | unit | max. value)
0
4294967295
Subcodes
Info
C02901/1
Size of the memory for quick download to RAM
C02901/2
Size of the memory for "Online change"
C02901/3
Size of the memory from which the cam data are
processed.
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1