C02568 | motor interface: % signals, C02569 | motor interface.: dig. signals, C02568/1 – Lenze 9400 User Manual
Page 859: C02568/2, C02568/3, C02569/2, C02568/4, C02568/5, C02568/7, C02568/8

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
859
14
Parameter reference
14.2
Parameter list | C02568
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02568
C02569
Parameter | Name:
C02568 | Motor interface: % signals
Data type: INTEGER_32
Index: 22007
d
= 55F7
h
Display of the scaled signals of the
.
Display range
(min. value | unit | max. value)
-200.00
%
200.00
Subcodes
Info
C02568/1
MI_dnPosCtrlAdaptLoad_n
C02568/2
MI_dnPosCtrlAdaptMotor_n
C02568/3
MI_dnSpeedCtrlAdapt_n
C02568/4
MI_dnTorqueHighLimit_n
C02568/5
MI_dnTorqueLowLimit_n
C02568/6
MI_dnTorqueCtrlAdapt_n
C02568/7
MI_dnFluxSetpoint_n
C02568/8
MI_dnInertiaAdapt_n
C02568/9
MI_dnBoostSet_n
C02568/10
MI_dnTorqueAdd_n
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100
Parameter | Name:
C02569 | Motor interface.: Dig. signals
Data type: UNSIGNED_32
Index: 22006
d
= 55F6
h
Display of the digital signals of the
.
Selection list
(read only)
0 FALSE
1 TRUE
Subcodes
Info
C02569/1
Reserved
C02569/2
MI_bResetSpeedCtrlIntegrator
C02569/3
MI_bLimitationActive
C02569/4
MI_bPosCtrlLimited
C02569/5
MI_bSpeedSetPointLimited
C02569/6
MI_bSpeedCtrlLimited
C02569/7
MI_bTorqueSetpointLimited
C02569/8
MI_bCurrentSetpointLimited
C02569/9
MI_bSpeedBelowC19
C02569/10
MI_bSpeedFollowingError
C02569/11
MI_bMotorOverloadWarning
C02569/12
MI_bMotorOrientationInverse
C02569/13
MI_bFlyingSyncBusy
C02569/14
MI_bClampIsActive
C02569/15
MI_bMagnetisationFinished
C02569/16
MI_bFlyingSyncBlocked
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1