C02590 | brake opening time, C02591 | waiting time - state monitoring, C02593 | waiting time - brake activation – Lenze 9400 User Manual
Page 864: C02594 | test torque, C02595 | permissible angle of rotation, C02590, C02591, C02593, C02594, C02595

14
Parameter reference
14.2
Parameter list | C02590
864
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02590
C02591
C02593
C02594
C02595
Parameter | Name:
C02590 | Brake opening time
Data type: UNSIGNED_32
Index: 21985
d
= 55E1
h
Basic function "
Setting range
(min. value | unit | max. value)
Lenze setting
0
ms
60000 100 ms
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02591 | Waiting time - state monitoring
Data type: UNSIGNED_32
Index: 21984
d
= 55E0
h
Basic function "
Setting range
(min. value | unit | max. value)
Lenze setting
0
ms
60000 100 ms
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02593 | Waiting time - brake activation
Data type: UNSIGNED_32
Index: 21982
d
= 55DE
h
Basic function "
Setting range
(min. value | unit | max. value)
Lenze setting
0.000
s
1000.000 0.000 s
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1000
Parameter | Name:
C02594 | Test torque
Data type: INTEGER_32
Index: 21981
d
= 55DD
h
Basic function "
Setting range
(min. value | unit | max. value)
Lenze setting
-21474836.47
Nm
21474836.47 0.00 Nm
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100
Parameter | Name:
C02595 | Permissible angle of rotation
Data type: INTEGER_32
Index: 21980
d
= 55DC
h
Basic function "
Setting range
(min. value | unit | max. value)
Lenze setting
0
°
36000 5 °
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1