C02528 | traversing range, C02529 | position encoder mounting dir, C02530 | active function state – Lenze 9400 User Manual
Page 851: C02528, Yed in, C02530, Aversing range, C02529, The currently active fun, 14 parameter reference

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
851
14
Parameter reference
14.2
Parameter list | C02528
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02528
C02529
C02530
Parameter | Name:
C02528 | Traversing range
Data type: UNSIGNED_32
Index: 22047
d
= 561F
h
Selection list
(Lenze setting printed in bold)
0 Unlimited
1 Limited
2 Modulo
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02529 | Position encoder mounting dir.
Data type: UNSIGNED_32
Index: 22046
d
= 561E
h
Selection list
(Lenze setting printed in bold)
0 Encoder rotating CW
1 Encoder rotating CCW
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02530 | Active function state
Data type: INTEGER_32
Index: 22045
d
= 561D
h
Displays the basic drive function that currently controls the drive.
Selection list
(read only)
0 Program stopped
1 Initial/boot state active
2 Torque follower active
3 Speed follower active
4 Position follower active
5 Setpoint follower active
6 Positioning active
7 Homing active
8 Manual jog active
9 Brake test active
10 Drive at standstill
11 Drive is stopped
12 Quick stop active
13 Reserve 1
14 Controller is not ready
15 Initialisation
16 Fault
17 Manual control open loop active
18 Pole position identification active
Read access Write access CINH PLC STOP No transfer