C02714 | max. dist. manual jog [inc, C02715 | limitation active, C02716 | resp. to limitation – Lenze 9400 User Manual
Page 887: C02717 | lim_dwcontrol, C02717, C02714, C02715, C02716/1, C02716/2, C02716/3

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
887
14
Parameter reference
14.2
Parameter list | C02714
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02714
C02715
C02716
C02717
Parameter | Name:
C02714 | Max. dist. manual jog [inc.]
Data type: UNSIGNED_32
Index: 21861
d
= 5565
h
Basic function "
Display range
(min. value | unit | max. value)
0
Incr.
2147483647
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02715 | Limitation active
Data type: UNSIGNED_32
Index: 21860
d
= 5564
h
Basic function "
Selection list
(read only)
0 Deactivated
1 Activated
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02716 | Resp. to limitation
Data type: UNSIGNED_32
Index: 21859
d
= 5563
h
Basic function "
Selection list
1 Fault
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information
0 No response
Subcodes
Lenze setting
Info
C02716/1
6: Information
Resp. to rotation limitation
C02716/2
3: Quick stop by trouble
Resp. to SW lim. pos. exceeded
C02716/3
6: Information
Resp. to max. value exceeded
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02717 | LIM_dwControl
Data type: UNSIGNED_32
Index: 21858
d
= 5562
h
Bit coded control word of the basic function "
Display range
(min. value | unit | max. value)
0
4294967295
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1