Inside the device: fan is defective [0x00770011, Device utilisation ixt > c00123 [0x00780000, Device utilisation ixt > 100 % [0x00780001 – Lenze 9400 User Manual
Page 645: Motor load i·xt > c00127 [0x00780002, Motor load i·xt > c00120 [0x00780003, 0x00780001, 0x00780000, 0x00770011, 0x00780003, 0x00780002

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
645
13
Diagnostics & fault analysis
13.7
Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Inside the device: Fan is defective [0x00770011]
Device utilisation Ixt > C00123 [0x00780000]
Device utilisation Ixt > 100 % [0x00780001]
Motor load I²xt > C00127 [0x00780002]
Motor load I²xt > C00120 [0x00780003]
Module ID (decimal)
Error ID (decimal)
119: Temperature monitoring
17
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Speed of internal fan is too low, e.g. due to dirt.
Check/clean fan.
Module ID (decimal)
Error ID (decimal)
120: Analog signal monitoring
0
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Frequent and too long acceleration processes with
overcurrent >
.
Check drive dimensioning.
Module ID (decimal)
Error ID (decimal)
120: Analog signal monitoring
1
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Frequent and too long acceleration processes with
overcurrent.
Check drive dimensioning.
Module ID (decimal)
Error ID (decimal)
120: Analog signal monitoring
2
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Motor is thermally overloaded, e.g. due to:
• impermissible continuous current
• frequent or too long acceleration processes
• Check drive dimensioning.
• Check setting in
.
Module ID (decimal)
Error ID (decimal)
120: Analog signal monitoring
3
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Motor is thermally overloaded, e.g. due to:
• impermissible continuous current
• frequent or too long acceleration processes
• Check drive dimensioning.
• Check setting in
.