Parameter list | C00588
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00588
C00589
C00591
Parameter | Name:
C00588 | Resp. to failure t. sensor drive
Data type: UNSIGNED_32
Index: 23987
d
= 5DB3
h
Response to error/failure of temperature sensor for heatsink temperature/temperature inside the controller
Selection list
(Lenze setting printed in bold)
1 Fault
5 Warning
0 No response
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00589 | Resp. to CPU temp. > C00126
Data type: UNSIGNED_32
Index: 23986
d
= 5DB2
h
Response if CPU temperature on the control card > variable limit temperature (
Selection list
(Lenze setting printed in bold)
1 Fault
5 Warning
0 No response
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00591 | Resp. to CAN-RPDOx error
Data type: UNSIGNED_8
Index: 23984
d
= 5DB0
h
Response if the corresponding CAN RPDO has not been received in the configured time or with the configured sync.
Selection list
(Lenze setting printed in bold)
1 Fault
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information
0 No response
Subcodes
Lenze setting
Info
C00591/1
0: No response
Response to non-received RPDO1 ... RPDO4
C00591/...
C00591/4
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1