C02641 | action after detect home position, C02642 | home position, C02643 | homing: target position – Lenze 9400 User Manual
Page 874: C02644 | homing: speed 1, C02642, C02643, C02644, C02641, Serves, Tting

14
Parameter reference
14.2
Parameter list | C02641
874
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02641
C02642
C02643
C02644
1028 DS402 homing method 28
1029 DS402 homing method 29
1030 DS402 homing method 30
1031 DS402 homing method 31
1032 DS402 homing method 32
1033 DS402 homing method 33
1034 DS402 homing method 34
1035 DS402 homing method 35
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02640 | Homing mode
Data type: UNSIGNED_32
Index: 21935
d
= 55AF
h
Parameter | Name:
C02641 | Action after detect Home position
Data type: UNSIGNED_32
Index: 21934
d
= 55AE
h
From software version V4.0
Basic function "
Selection list
(Lenze setting printed in bold)
0 Move absolute on target position
1 Move relative by Target position
2 Stop immediately
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02642 | Home position
Data type: INTEGER_32
Index: 21933
d
= 55AD
h
Basic function "
Setting range
(min. value | unit | max. value)
Lenze setting
-214748.3647
Unit
214748.3647 0.0000 Unit
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10000
Parameter | Name:
C02643 | Homing: Target position
Data type: INTEGER_32
Index: 21932
d
= 55AC
h
Basic function "
Setting range
(min. value | unit | max. value)
Lenze setting
-214748.3647
Unit
214748.3647 0.0000 Unit
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10000
Parameter | Name:
C02644 | Homing: Speed 1
Data type: INTEGER_32
Index: 21931
d
= 55AB
h
Basic function "
Setting range
(min. value | unit | max. value)
Lenze setting
0.0000
Unit/s
214748.3647 360.0000 Unit/s
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10000