Motor stator resistance
For the adjustment of the motor stator resistance, first the motor current at standstill (without load
of the motor) is compared to the motor magnetising current. Afterwards the setting of the motor
stator resistance is changed step by step until the motor current stably reaches the motor
magnetising current.
How to adjust the motor stator resistance:
1. Select setpoint speed 0 rpm or activate quick stop.
2. Enable controller.
3. Compare the motor current displayed in
with the motor magnetising current
displayed in
4. Inhibit controller.
5. If motor current > motor magnetising current:
• Reduce the motor stator resistance stepwise in
.
If motor current < motor magnetising current:
• Increase the motor stator resistance stepwise in
6. Repeat steps 2 ... 5 until the following applies: Motor current ≈ motor magnetising current.
7. Save parameter set (