C00053 | dc-bus voltage, C00054 | motor current, C00055 | phase currents – Lenze 9400 User Manual
Page 736: C00056 | torque setpoint, C00057 | torque, C00054, C00057/1, C00057/2, Rrent displayed in, With t

14
Parameter reference
14.2
Parameter list | C00053
736
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00053
C00054
C00055
C00056
C00057
Parameter | Name:
C00053 | DC-bus voltage
Data type: UNSIGNED_32
Index: 24522
d
= 5FCA
h
Display range
(min. value | unit | max. value)
0
V
2147483647
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00054 | Motor current
Data type: UNSIGNED_32
Index: 24521
d
= 5FC9
h
Display range
(min. value | unit | max. value)
0.00
A
500.00
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100
Parameter | Name:
C00055 | Phase currents
Data type: INTEGER_32
Index: 24520
d
= 5FC8
h
Display range
(min. value | unit | max. value)
-500.00
A
500.00
Subcodes
Info
C00055/1
Phase zero system
C00055/2
Phase U
C00055/3
Phase V
C00055/4
Phase W
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100
Parameter | Name:
C00056 | Torque setpoint
Data type: INTEGER_32
Index: 24519
d
= 5FC7
h
Display range
(min. value | unit | max. value)
-21474836.47
Nm
21474836.47
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100
Parameter | Name:
C00057 | Torque
Data type: UNSIGNED_32
Index: 24518
d
= 5FC6
h
Display range
(min. value | unit | max. value)
0.000
Nm
2147483.647
Subcodes
Info
C00057/1
Maximum torque
• With regard to the selected motor and the max. short-
time output current of the device.
C00057/2
Motor reference torque
• Torque at maximum current (
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1000