2 parameter setting, 11 basic drive functions – Lenze 9400 User Manual
Page 386

11
Basic drive functions
11.2
Stop
386
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.2.2
Parameter setting
• Parameterisation dialog in »Engineer«: Tab Application parameter Dialog level Overview
All basic functions Stop
• Short overview of parameters for standard stop :
Parameter setting of stop
[11-6] Deceleration time referred to the motor reference speed
[11-7] Deceleration time referred to the current speed
[11-8] S-shaped deceleration ramp through selection of a relative S-ramp time
Parameter
Info
Deceleration time for stop
S-ramp time for stop
Ref. for decel. time of stop
• The deceleration time for stop set in
refers to a speed variation from
standstill, i. e. the deceleration is constant.
n
t
C00011
C02610
is set = "1", the deceleration
time refers to the current speed, i. e. the
braking time is constant.
C02610
n
t
C00011
• By entering an S-ramp time in
deceleration ramp can be set in an S-
shaped manner for purposes of jerk
limitation; the total time until standstill is
then extended by the S-ramp time
set.
• Braking time at motor reference speed or
= "1":
n
t
C00011
n
t
C00011
C02612 = 0
C02612 = 1
C02610 + C02611
C02610 [s] C02611 [s]
+