C02605 | brake test - time, C02607 | brk_dnstate, C02608 | brk_dntorqueadd_n – Lenze 9400 User Manual
Page 867: C02608, C02607, C02605/1, C02605/2, C02605/3, 14 parameter reference

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
867
14
Parameter reference
14.2
Parameter list | C02605
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02605
C02607
C02608
Parameter | Name:
C02605 | Brake test - time
Data type: UNSIGNED_16
Index: 21970
d
= 55D2
h
From software version V10.0
Setting range
(min. value | unit | max. value)
0.001
s
65.535
Subcodes
Lenze setting
Info
C02605/1
1.024 s
Brake test - ramp-up time
C02605/2
4.000 s
Brake test - constant ph. time
C02605/3
1.024 s
Brake test - ramp-down time
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1000
Parameter | Name:
C02607 | BRK_dnState
Data type: INTEGER_32
Index: 21968
d
= 55D0
h
Bit coded status of the basic function "
".
Display range
(min. value | unit | max. value)
-2147483648
2147483647
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02608 | BRK_dnTorqueAdd_n
Data type: INTEGER_32
Index: 21967
d
= 55CF
h
Display of the additive torque value of the basic function "
Display range
(min. value | unit | max. value)
-200.00
%
200.00
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100