C00952 | vfc: frequency interpol. point n, C00953 | vfc: voltage interpol. point n, C00952/1 – Lenze 9400 User Manual
Page 823: C00953/1, C00952, C00953, 14 parameter reference

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
823
14
Parameter reference
14.2
Parameter list | C00952
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00952
C00953
Parameter | Name:
C00952 | VFC: Frequency interpol. point n
Data type: INTEGER_32
Index: 23623
d
= 5C47
h
From software version V3.0
Setting range
(min. value | unit | max. value)
-5000
Hz
5000
Subcodes
Lenze setting
Info
C00952/1
-50 Hz
C00952/2
-40 Hz
C00952/3
-30 Hz
C00952/4
-20 Hz
C00952/5
-10 Hz
C00952/6
0 Hz
C00952/7
10 Hz
C00952/8
20 Hz
C00952/9
30 Hz
C00952/10
40 Hz
C00952/11
50 Hz
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00953 | VFC: Voltage interpol. point n
Data type: INTEGER_32
Index: 23622
d
= 5C46
h
From software version V3.0
Setting range
(min. value | unit | max. value)
0.00
V
1000.00
Subcodes
Lenze setting
Info
C00953/1
400.00 V
C00953/2
320.00 V
C00953/3
240.00 V
C00953/4
160.00 V
C00953/5
80.00 V
C00953/6
0.00 V
C00953/7
80.00 V
C00953/8
160.00 V
C00953/9
240.00 V
C00953/10
320.00 V
C00953/11
400.00 V
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100