4.2.14
Reset runtime measurement
When the application is started, the controller continuously carries out a runtime measurement for
the interval-controlled application task, the interval-controlled user task, and the free-running idle
task and displays the current and maximum task runtimes via parameters.
The
= "36: Reset runtime measurement" device command is used to reset the runtime
measurement, i.e. the memory for the maximum values is reset to "0".
Possible status displays for this device command
Example for runtime measurement
[4-19] Example: Runtimes of the different tasks
Status (
Meaning
2393346 Device command in process
2359296 Device command executed successfully
2359297 General fault
Note!
The runtime measurement is also reset by the following actions:
• Start application
• Reset/delete/restart program
System task
Application task (here: task interval = 1 ms)
User task (here: task interval = 4 ms)
Free-running idle task
T1 = runtime of the application task
T2 = runtime of the user task
T3 = runtime of the idle task