11
Basic drive functions
11.12
Brake control
522
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.12.2.1 Operating mode
Various operating modes are available in
for different applications and tasks:
•
Mode 0: Brake control is switched off
•
Mode 1/11: Direct control of the brake
• Without a specific logic or automatic system, can for instance be used to carry out a simple
check on whether the brake switches correctly.
•
Mode 2/12: Automatic control of the brake
• The normal mode for the control of mech. holding brakes with and without holding torque
precontrol.
Function extension from software version V3.0:
•
Mode 22: Automatic DC-injection braking
• DC-injection braking for V/f control and sensorless vector control.
Source for feedf. control brake
Threshold 1 for opening brake
Threshold 2 for opening brake
Acceleration time - brake test
Duration of constant torque - brake test
Deceleration time - brake test
Parameter
Info