Resolver: open circuit [0x007b0018, Ching on the controller, 0x007b001a – Lenze 9400 User Manual
Page 652: 0x007b0019, 0x007b0018, 13 diagnostics & fault analysis

13
Diagnostics & fault analysis
13.7
Error messages of the operating system
652
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Resolver: Open circuit [0x007b0018]
Motor: Calculated leakage inductance unrealistic [0x007b0019]
Absolute value encoder: Communication error [0x007b001a]
Module ID (decimal)
Error ID (decimal)
123: Motor control
24
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
• Resolver cable interrupted.
• Resolver defective.
• Check resolver cable.
• Check resolver.
• Switch off the monitoring function (
="3") if no
resolver is used.
Module ID (decimal)
Error ID (decimal)
123: Motor control
25
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Faulty motor parameterisation.
Check motor parameters.
Module ID (decimal)
Error ID (decimal)
123: Motor control
26
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Absolute value encoder does not send any data or a
digital readout has been activated while the machine is
coasting down.
• Check supply cable.
• Check encoder.
• Check voltage supply (
).
• For Hiperface absolute value encoders: Check the
initialisation time (
).