Basic drive functions
11.6
Homing
430
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Mode 3: neg. direction - reversing to limit switch - via home mark - to TP
Procedure:
1. Movement in negative direction with profile data set 1.
2. Reversing to negative travel range limit switch.
3. Positive edge at HM_bHomingMark activates profile data set 2 for the further reference search.
4. Negative edge at HM_bHomingMark enables home position detection.
5. The following positive edge of the encoder zero pulse/touch probe sensor sets the reference.
6. Absolute positioning to target position (
) with profile data set 2 (if
= "0").
Touch probe/zero pulse
Reference switch
Negative travel range limit switch
1
0
1
2