Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
99
4
Drive interface
4.3
Device states
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Influence of the status signals of the SB LS_DriveInterface by the device state
Internal interfaces | "LS_DriveInterface" system block
4.3.1
"Initialisation active" state
This is the controller's state directly after switching on the supply voltage.
• In this device state the operating system is initialised.
• The monitoring functions are not active yet.
• Communication is not possible yet.
• The controller cannot be parameterised yet and no device commands can be executed.
• When the device initialisation is completed, the device state is automatically changed to "Safe
torque off active".
Status signals
(Outputs of the SB
Device status
DI_bReady
DI_bFail
Active
DI_bImp
Active
DI_bCInh
Active
DI_bWarning
Active
DI_bReady
ToSwitchOn
DI_bOperation
Enabled
FALSE
FALSE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
FALSE
TRUE
TRUE
TRUE/FALSE
FALSE
FALSE
FALSE
FALSE
TRUE
TRUE
TRUE/FALSE
TRUE
FALSE
TRUE
FALSE
TRUE
TRUE
TRUE/FALSE
FALSE
FALSE
TRUE
FALSE
FALSE
FALSE
TRUE/FALSE
FALSE
TRUE
TRUE/FALSE
TRUE/FALSE
TRUE/FALSE
TRUE/FALSE
TRUE
TRUE/FALSE
TRUE/FALSE
TRUE/FALSE
TRUE/FALSE
TRUE/FALSE
TRUE/FALSE
TRUE
TRUE/FALSE
TRUE/FALSE
FALSE
TRUE
FALSE
FALSE
TRUE/FALSE
FALSE
FALSE
FALSE
FALSE
TRUE
TRUE
TRUE/FALSE
FALSE
FALSE
FALSE
TRUE
TRUE
TRUE
TRUE/FALSE
FALSE
FALSE
FALSE
TRUE
TRUE
TRUE
TRUE/FALSE
FALSE
FALSE
LED DRIVE READY
LED DRIVE ERROR
OFF
OFF
10: Initialisation active