C00227 | behaviour due to change of parameter set, C00254 | phase controller gain, C00270 | freq. - current setpoint filter – Lenze 9400 User Manual
Page 761: C00271 | width - current setp. filter, C00270/1, C00270/2, C00271/1, C00271/2, Y in, C00272/1

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
761
14
Parameter reference
14.2
Parameter list | C00227
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00227
C00254
C00270
C00271
Parameter | Name:
C00227 | Behaviour due to change of parameter set
Data type: UNSIGNED_32
Index: 24348
d
= 5F1C
h
From software version V5.0
By selecting "1" in the corresponding subcode a module plugged into module slot MXI1 or MXI2 can be excepted
from the parameter set changeover via the device command "Activate parameter set n".
• By this the parameter set changeover, in particular for active modules, is carried out much more quickly.
• An exception from the parameter set changeover for instance is reasonable if different parameter sets are used
(e. g. for different tools within the machine), but if the parameters are always the same for the module (e. g.
communication parameters).
Selection list
(Lenze setting printed in bold)
0 Included
1 Excluded
Subcodes
Lenze setting
Info
C00227/1
0: Included
Change of parameter set: MXI1
C00227/2
0: Included
Change of parameter set: MXI2
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00254 | Phase controller gain
Data type: UNSIGNED_32
Index: 24321
d
= 5F01
h
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
1/s
1000.00 20.00 1/s
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100
Parameter | Name:
C00270 | Freq. - current setpoint filter
Data type: UNSIGNED_32
Index: 24305
d
= 5EF1
h
Set current setpoint filter (band-stop filter)
Setting range
(min. value | unit | max. value)
1.0
Hz
1000.0
Subcodes
Lenze setting
Info
C00270/1
200.0 Hz
Freq. - current setp. filter 1
C00270/2
400.0 Hz
Freq. - current setp. filter 2
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10
Parameter | Name:
C00271 | Width - current setp. filter
Data type: UNSIGNED_32
Index: 24304
d
= 5EF0
h
Set current setpoint filter (band-stop filter)
Setting range
(min. value | unit | max. value)
0.0
Hz
500.0
Subcodes
Lenze setting
Info
C00271/1
20.0 Hz
Width current setp. filter 1
C00271/2
40.0 Hz
Width current setp. filter 2
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10