C02830 | digital inputs: delay time, C02830, 14 parameter reference – Lenze 9400 User Manual
Page 900

14
Parameter reference
14.2
Parameter list | C02830
900
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02830
C02850
C02851
C02852
Parameter | Name:
C02830 | Digital inputs: Delay time
Data type: UNSIGNED_8
Index: 21745
d
= 54F1
h
Input filter for digital inputs
• Can be used to filter out "spikes" at the digital inputs, if necessary.
• Each digital input is assigned to a subcode.
• Since the filter is a "counting" filter, the indicated times are only approximate values.
Selection list
(Lenze setting printed in bold)
Info
0 2 μs
Filter time
1 4 μs
2 8 μs
3 16 μs
4 32 μs
5 64 μs
6 128 μs
7 256 μs
8 512 μs
9 1024 μs
10 2048 μs
11 4096 μs
12 8192 μs
13 16384 μs
14 32768 μs
Subcodes
Lenze setting
Info
C02830/1
0: 2 μs
Setting for digital input 1 ... 8
C02830/...
C02830/8
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02850 | Service code
Data type: UNSIGNED_32
Index: 21725
d
= 54DD
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C02851 | Service code
Data type: UNSIGNED_32
Index: 21724
d
= 54DC
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C02852 | Service code
Data type: UNSIGNED_16
Index: 21723
d
= 54DB
h
This code is for device-internal use only and must not be written to by the user!